Commissioning
8.5 Commissioning with the STARTER commissioning tool
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
311
Figure 8-26 Entering encoder data – Pulse encoder via SMC30
⇒
Select the encoder connection (SUB-D /terminal).
⇒
Enter the required encoder data.
⇒
Click on OK
NOTICE
Material damage when selecting the incorrect encoder supply voltage
Once the encoder has been commissioned, the supply voltage (5 V / 13.5 - 30 V) set for the
encoder is activated on the SMC30 Module. If a 5 V encoder is connected and the supply
voltage has not been set correctly, the encoder may be damaged.
•
Set the correct supply voltage for the connected encoder.
⇒
Click on Next >