Descriptions of functions
10.18 Switching on auxiliary circuits
SINAMICS DCM DC Converter
580
Operating Instructions, 12/2018, A5E34763375A
Figure 10-65 Operational brake (p50080 = 2), brake opening time (p50087) negative
Footnotes for the two figures above
<1>
Mechanical deceleration of drive by means of operational brake
<2>
Drive coasting down; "Close holding brake" first applied when n < nmin
<4>
Here, motor works against the brake, which is still closed (p50087 negative)
<5>
Time for brake to be closed, during which motor continues to apply torque (p50088)
Figure 10-66 Holding brake (p50080 = 1), brake opening time (p50087) negative