Commissioning
8.5 Commissioning with the STARTER commissioning tool
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
309
[5] DRIVE-CLiQ encoder: Resolver via Sensor Module Cabinet SMC10
The resolver is connected via the Sensor Module Cabinet SMC10.
⇒
Select encoder 2 to activate the evaluation of the encoder via the Sensor Module Cabinet
SMC10.
⇒
To select a predefined encoder configuration click on the radio button Select standard
encoder from list, and select one of the encoders that is listed.
The following resolvers can be evaluated via the Sensor Module Cabinet SMC10:
●
[1001] resolver 1-speed
●
[1002] Resolver 2-speed
●
[1003] Resolver 3-speed
●
[1004] Resolver 4-speed
⇒
To enter special encoder configurations, click the Enter data radio button and then the
Encoder data button. The following input screen is displayed for you to enter the required
data.
Figure 8-25 Entering encoder data – Resolver via SMC10
⇒
Enter the pole pair number.
⇒
Click on OK