Applications
12.4 Using SINAMICS DCM as thyristor controller in heating applications
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
707
Figure 12-4 Voltage and current curves
In order to be able to control the load current, it is recommended that an external actual
current sensing circuit be used for these applications. Whereby, the entire load current
(including the freewheeling current) is measured via an external shunt. The shunt voltage
must be increased via an external shunt converter and then led to the SINAMICS DCM via
an analog input. See function diagram 6850, column 2.
Figure 12-5 SINAMICS DCM with external current actual value sensing
Parameter
p51852
Selection of external current actual value sensing
p51853
Scaling of external current actual value sensing