Technical data
4.5 Unit data
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
47
Table 4- 8
Technical data for 3-ph. 400 V AC, 280 to 850 A, 2Q devices
Article number 6RA80 ..
..78-6DS22-...
..81-6DS22-...
..85-6DS22-...
..87-6DS22-...
Rated DC current
A
280
400
600
850
Rated armature input current
2)
A
232
332
498
706
Rated power
kW
136
194
291
412
Power loss at
rated DC current (approx.)
W
812
1375
1844
2467
Rated field supply voltage
1)
V
2-ph. 400 V AC (+15% / -20%)
Rated field DC voltage
1)
V
325
325
325
325
Rated field DC current
A
15
25
25
30
Type of cooling
Forced
ventilation
Forced
ventilation
Forced
ventilation
Forced
ventilation
Rated fan supply voltage
V
Fan with internal
power supply
3-ph. 400 V AC (±15%) 50 Hz / clockwise phase
sequence
3-ph. 460 V AC (±10%) 60 Hz / clockwise phase
sequence
With option L21: 1-ph. 230 V AC (±10%)
Rated fan current
50 Hz
60 Hz
A
-
0.23
8)
0.26
8)
0.23
8)
0.26
8)
0.23
8)
0.26
8)
Rated fan current
with option L21
50 Hz
60 Hz
A
-
0.51
8)
0.72
8)
0.51
8)
0.72
8)
0.51
8)
0.72
8)
Fan air flow
m
3
/h
300
600
600
600
Fan noise level
50 Hz
60 Hz
dB(A)
70.3
70.3
70.3
74.4
70.3
74.4
70.3
74.4
Dimensions (WxHxD)
mm
268x385x252
268x625x275
268x625x275
268x700x311
Weight (approx.)
kg
15
26
28
38
Содержание SINAMICS Series
Страница 1: ......
Страница 2: ......
Страница 744: ...Appendix A A 4 Servicing SINAMICS DCM DC Converter 742 Operating Instructions 12 2018 A5E34763375A ...
Страница 758: ......