Error
Code
Diag.
Code
Device
Display
Meaning for the LMV5x System
Corrective Action
23
Unplaus Value
Ri 02 Measuring
Cell
Measured internal resistance of the QGO measuring cell
is smaller than 5 Ohm or greater than 150 Ohm
1) Check the wiring between the O2 Module and the O2
sensor.
2) O2 Sensor may have reached the end of its service
life (check resistance through AZL -
QGO Resistance
).
If greater than 140 - 150 ohms, replace sensor.
24
Response Time
O2
Measuring Cell
too long
Measured response time of the QGO measuring cell
exceeds 5 seconds
(completely electronic)
1) Check mounting position / orientation of O2 sensor.
2) Check to see if O2 sensor is dirty. Do not blow out
with compresed air when hot! Cool, then blow out with
low pressure compressed air (less than 10 psi)
3) O2 Sensor may have reached the end of its service
life (check resistance through AZL -
QGO Resistance
).
If greater than 140 -150 ohms, replace sensor.
25
O2 Sensor Test
aborted by O2
Module
Fault occurred during O2 sensor test
Check (through the AZL -
Normal Operation
) to see if
the measured O2 value is fluctuating.
30
CAN fault
1) If fault occurs sporadically, reduce electrical noise.
2) If fault occurs constantly, replace PLL5..
31
CRC fault of a parameter page
32
Page too long open
33
Page disrupted
34
Invalid access to parameters
38
Fault during copying of a parameter page
3E
External plausibility fault. This type of fault covers possible
faults occurring due to invalid presettings in the drive
commands. In response, the presettings will be ignored.
3F
Internal plausibility fault. This type of fault covers possible
errors that cannot practically occur.
1) If fault occurs sporadically, reduce electrical noise.
2) If fault occurs constantly, replace PLL5..
Any #
Fault during test of port outputs
01
Fault when resetting the set outputs
02
Fault during ZR test
B1
01
Fault during short-circuit test between inputs and outputs
Fault with 02 Module (PLL5..) or Oxygen Sensor (QGO2..)
Fault with Base Unit (LMV5)
B0
1) Reset the LMV5
2) If fault occurred after changing a parameter, check
the parameters that were last changed.
3) If fault cannot be rectified by the reset: Restore
parameters from the AZL to the LMV5
4) Replace the LMV5
PLL5..
1) If fault occurs sporadically, reduce electrical noise.
2) If fault occurs continuously, replace LMV5.
AB
Internal Fault O2
Module
LMV5..
Internal Fault
Basic Unit
Section 7
Page 54
SCC Inc.
HOME
HOME
Содержание LMV 5 Series
Страница 2: ...Intentionally Left Blank ...
Страница 25: ...LMV Series Technical Instructions Document No LV5 1000 SCC Inc Page 21 Section 1 Intentionally Left Blank HOME ...
Страница 27: ...LMV Series Technical Instructions Document No LV5 1000 SCC Inc Page 23 Section 1 Intentionally Left Blank HOME ...
Страница 41: ...LMV Series Technical Instructions Document No LV5 1000 SCC Inc Page 7 Section 2 HOME ...
Страница 42: ...Technical Instructions LMV Series Document No LV5 1000 Section 2 Page 8 SCC Inc HOME ...
Страница 43: ...LMV Series Technical Instructions Document No LV5 1000 SCC Inc Page 9 Section 2 HOME ...
Страница 44: ...Technical Instructions LMV Series Document No LV5 1000 Section 2 Page 10 SCC Inc HOME ...
Страница 45: ...LMV Series Technical Instructions Document No LV5 1000 SCC Inc Page 11 Section 2 HOME ...
Страница 46: ...Technical Instructions LMV Series Document No LV5 1000 Section 2 Page 12 SCC Inc HOME ...
Страница 47: ...LMV Series Technical Instructions Document No LV5 1000 SCC Inc Page 13 Section 2 HOME ...
Страница 48: ...Technical Instructions LMV Series Document No LV5 1000 Section 2 Page 14 SCC Inc HOME ...
Страница 49: ...LMV Series Technical Instructions Document No LV5 1000 SCC Inc Page 15 Section 2 HOME ...
Страница 50: ...Technical Instructions LMV Series Document No LV5 1000 Section 2 Page 16 SCC Inc HOME ...
Страница 51: ...LMV Series Technical Instructions Document No LV5 1000 SCC Inc Page 17 Section 2 HOME ...
Страница 52: ...Technical Instructions LMV Series Document No LV5 1000 Section 2 Page 18 SCC Inc HOME ...
Страница 53: ...LMV Series Technical Instructions Document No LV5 1000 SCC Inc Page 19 Section 2 HOME ...
Страница 54: ...Technical Instructions LMV Series Document No LV5 1000 Section 2 Page 20 SCC Inc HOME ...
Страница 55: ...LMV Series Technical Instructions Document No LV5 1000 SCC Inc Page 21 Section 2 HOME ...
Страница 56: ...Technical Instructions LMV Series Document No LV5 1000 Section 2 Page 22 SCC Inc Intentionally Left Blank HOME ...
Страница 116: ...Technical Instructions LMV Series Document No LV5 1000 Section 3 Page 58 SCC Inc Intentionally Left Blank HOME ...
Страница 150: ...Technical Instructions LMV Series Document No LV5 1000 Section 4 Page 32 SCC Inc Intentionally Left Blank HOME ...
Страница 170: ...Technical Instructions LMV Series Document No LV5 1000 Section 5 Page 18 SCC Inc Intentionally Left Blank HOME ...
Страница 290: ...Technical Instructions LMV Series Document No LV5 1000 Section 8 Page 20 SCC Inc Intentionally Left Blank HOME ...
Страница 306: ...Technical Instructions LMV Series Document No LV5 1000 Section 9 Page 14 SCC Inc Intentionally Left Blank HOME ...
Страница 373: ...Intentionally Left Blank ...