Digital input/ output parameter group 03
PARAMETER DESCRIPTION 95
5.4.7 Output frequency detection
Detects the inverter output frequency and output signal.
Parameter
Name
Default
Setting Range
Content
03-20
P.41
Output frequency detection
sensitivity
10.0%
0~100.0%
---
03-21
P.42
Output frequency detection
for forward rotation
6.00Hz
0~599.00Hz
---
03-22
P.43
Output frequency detection
for reverse rotation
99999
0~599.00Hz
---
99999
Same setting as 03-21(P.42).
Output frequency detection range
If 03-20(P.41)=5%, SU signal will be output when output frequency falls within “5% range around target frequency”.
For example, the target frequency is set to 60Hz and 03-20(P.41)=5%, then when output frequency falls within the
range of 60±60×5%=57Hz~63Hz, SU signal will be output.
A-C
Adjust range
03-20
(
P.41
)
O
ut
pu
t f
re
qu
en
cy
(
H
z)
Target
frequency
Output
signal
OFF
OFF
ON
Time
(
s
)
Forward/Reverse rotation output frequency detection
If 03-21(P.42)=30 and 03-22(P.43)=20, FU signal will output when forward rotation frequency exceeds 30Hz; and
when reverse rotation frequency exceeds 20Hz, FU signal will also be output.
If 03-21(P.42)=30 and 03-22(P.43)=99999 (default), FU signal will output when forward and reverse rotation
frequency exceed 30Hz.
A-C
O
ut
pu
t
fr
eq
ue
nc
y
(
H
z)
Output
signal
OFF
OFF
ON
Time
(
s
)
03-21(P.42)
03-22(P.43)
ON
OFF
Forward
Reverse
Note: SU and FU mentioned in this paragraph are the function names for digital output. Please refer to 03-11(P.85)
for
details, and section 3.7 for relevant wiring.