Digital input/ output parameter group 03
PARAMETER DESCRIPTION 85
5.4 Digital input/ output parameter group 03
Group
Parameter
Number
Name
Setting Range
Default Page
03-00
P.83
Terminal STF input
function
0: STF(Inverter runs forward)
0
1: STR(Inverter runs reverse)
2: RL(Multi-speed low speed)
3: RM(Multi-speed medium speed)
4: RH(Multi-speed high speed)
5: Reserved
6: External thermal relay actuate
7: MRS(Stops inverter output immediately)
8: RT(Inverter second function)
9: EXT(External JOG)
10:STF+EXJ
11:STR+EXJ
12:STF+RT
13:STR+RT
14:STF+RL
15:STR+RL
16:STF+RM
17:STR+RM
18:STF+RH
19:STR+RH
20:STF+RL+RM
21:STR+RL+RM
22:STF+RT+RL
23:STR+RT+RL
24:STF+RT+RM
25:STR+RT+RM
26:STF+RT+RL+RM
27:STR+RT+RL+RM
28: RUN(Inverter runs forward)
29: STF/STR(use with RUN signal, when ON, motor
runs reverse; when OFF, motor runs forward)
30: RES(External reset function)
31: STOP(Use as three line control with RUN signal and
STF-STR signal)
32: REX(Extend multi-speed to 16 levels)
33: PO(In “external mode", run programmed operation)
34: RES_E (External reset, valid only when alarm.)
35: MPO (In “external mode” run manual cycle
operation.)
36: TRI(Triangle wave function)