Appendix 1 Parameter table
Appendix 184
Group
Parameter
Number
Name
Setting Range
Default Page
04-36
P.112
Programmed operation mode
speed 2 Acc/Dec time
0~600.00s/0~6000.0s
0.00s
04-37
P.113
Programmed operation mode
speed 3 Acc/Dec time
0~600.00s/0~6000.0s
0.00s
04-38
P.114
Programmed operation mode
speed 4 Acc/Dec time
0~600.00s/0~6000.0s
0.00s
04-39
P.115
Programmed operation mode
speed 5 Acc/Dec time
0~600.00s/0~6000.0s
0.00s
04-40
P.116
Programmed operation mode
speed 6 Acc/Dec time
0~600.00s/0~6000.0s
0.00s
04-41
P.117
Programmed operation mode
speed 7 Acc/Dec time
0~600.00s/0~6000.0s
0.00s
04-42
P.118
Programmed operation mode
speed 8 Acc/Dec time
0~600.00s/0~6000.0s
0.00s
05-01
P.302
Motor rated power
0~160.00kW
0.00kW
05-02
P.303
Motor poles
0~48
4
05-03
P.304
Motor rated voltage
0~510V
According
to voltage
05-04
P.305
Motor rated frequency
50Hz system:0~599.00Hz
50.00Hz
60Hz system:0~599.00Hz
60.00Hz
05-05
P.306
Motor rated current
0~500.00A
According
to kw
05-06
P.307
Motor rated rotation speed
50Hz system:0~9998r/min
1410r/min
60Hz system: 0~9998r/min
1710r/min
05-07
P.308
Motor excitation current
0~500.00A
According
to kw
05-08
P.309
IM motor stator resistance
0~99.98Ω
According
to kw
06-00
P.9
Electronic thermal relay
capacity
0~500.00A
0.00
06-01
P.22
Stall prevention operation
level
0~200%
150%
06-02
P.23
Stall prevention operation
level correction factor
0~200%
99999
99999: Stall prevention operation level is the setting
value of 06-01(P.22).
06-03
P.66
Stall prevention operation
reduction starting frequency
50Hz system: 0~599.00Hz
50.00Hz
60Hz system: 0~599.00Hz
60.00Hz
06-08
P.155
Over torque detection level
0~200.0%
0.0%
06-09
P.156
Over torque detection time
0~60.0s
1.0s
06-10
P.260
Action when detect over
torque
0: OL2 alarm will not be reported after over torque
detection, and inverter keeps running.
1
1: OL2 alarm will be reported after over torque
detection, and inverter stops.
06-13
P.281
Input phase loss protection
0: Off
0
1: When input phase loss, built-in keypad shows IPF
alarm and inverter stops