System parameter group 00
PARAMETER DESCRIPTION 53
5.1.6 Built-in keypad set target frequency selection
Parameter
Name
Default
Setting Range
Content
00-10
P.59
Built-in keypad set
target frequency
selection
0
XXX0
Use up down button on built-in or external keypad to set
frequency
XXX1
Use keypad knob on external keypad to set frequency
XXX2
Use keypad knob on built-in keypad to set frequency
X0XX
Every frequency change will save after 30s
X1XX
Every frequency change will save after 10s
X2XX
Every frequency change will not save
0XXX
Set frequency will work immediately when use up down
button on built-in keypad
1XXX
Set frequency will work after pressing SET when use up
down button on built-in keypad
Built-in keypad set target frequency selection
00-10(P.59)is set by unit, 4 in total.
0:Set frequency will work immediately when use up down
button on built-in keypad
1:Set frequency will work after pressing SET when use up
down button on built-in keypad
00-10 (P.59)
0
0
0
0:Use up down button on built-in or external keypad to
set frequency
1:Use keypad knob on external keypad to set frequency
2:Use keypad knob on built-in keypad to set frequency
Reserved
0:Every frequency change will save after 30s
1:Every frequency change will save after 10s
2:Every frequency change will not save
=
Note: 1. The set value on the hundreds digit of 00-10 (P.59) is only for the frequency set by up down keys on keypad.
2. When 00-10 (P.59) ones digit is 1, if the external keypad has a VR knob, the VR knob setting frequency is valid.
If the
external keypad does not have a VR knob, then up down keys of the external keypad is valid.
Setting
g