Application parameter group 10
PARAMETER DESCRIPTION 148
Triangular wave function
If 10-23(P.234) set to 1, triangular wave function will be on when terminal function TRI is triggered. Please set one
of 03-00(P.83)、03-01(P.84)、03-03(P.80)、03-04(P.81) as “36”, and then give TRI signals to the digital input
terminal.
If 10-23(P.234) set to 2, triangular wave function will be on all the time.
f0
f1
f1
f2
f3
Triangular wave operation
Run
signal
TRI signal
Time
10-28
(
P.239
)
f0: Frequency set
f1:Generated amplitude from
frequency set
f2: Compensation for switching from
acceleration to deceleration
f3: Compensation for switching
from deceleration to
acceleration
(f1× 10-26(P.237))
O
ut
pu
t
fre
qu
en
cy
10-27
(
P.238
)
(f0× 10-25(P.235))
(f1× 10-25(P.236))
01-06
(
P.7
)
01-07
(
P.8
)
01-06
(
P.7
)
Note: 1. Output frequency is limited by the upper and lower frequency limits in triangular wave operation.
2. If the values of amplitude compensation 10-25(P.236) and 10-26(P.237), are too large, overvoltage trip and
stall prevention protection will trigger.
5.10.11 Voltage stall action level
This parameter is used to set the voltage stall action discrimination level
Parameter
Name
Default
Setting Range
Content
10-46
P.268
Voltage stall level
380V
155~400V
220V model
760V
310~800V
440V model
Voltage stall action level
When the inverter's DC bus voltage is higher than the setting of 10-46 (P.268), the inverter is in voltage stall state.
5.10.12 Reciprocating machine function
Special functions for reciprocating machine according to customer needs.
Parameter
Name
Default Setting Range
Content
10-55
P.226
Reciprocating machine
function selection
0
0
Off
1
Turn on reciprocating machine function
10-56
P.227
Reciprocating forward
limit time
0.0s
0~3600.0s
Run forward for more than 10-56 (P.227) time, inverter will
decelerate to stop. When set to 0, this function is invalid.
10-57
P.228
Reciprocating reverse
limit time
0.0s
0~3600.0s
Run reverse for more than 10-57(P.228) time, inverter will
decelerate to stop. When set to 0, this function is invalid.
Reciprocating machine function
Setting
Setting
Setting
Содержание SL3 Series
Страница 2: ......
Страница 107: ......
Страница 200: ...Appendix 4 Optional equipment Appendix 196 ...
Страница 209: ...Appendix 5 European Specification Compatibility Description Appendix 205 3 CE Self Declaration ...
Страница 210: ...Appendix 5 European Specification Compatibility Description Appendix 206 ...