23-18
Computer Link
23
- Data that are set to "NO" output do not output any signal (scrolled up).
- Set the next page for details about the output codes (type, number of bytes, related measurement
programs)
Ex.: Output data examples when the "SERIAL OUTPUT" column is set to "YES."
23-5 Specifications for any output data
When the serial output is set to "ANY" (page 21-28), the measurement results for the output data that
is set to "YES" (page 21-28) will be written into the write register map "output data from
measurements 0 to 4 (block 0): *6 on page 23-3," in output-code order.
SHARP Mitsubishi
OMRON
Output
data
Details
Measurement item
when SERIAL
OUTPUT is set to
"YES"
09014
D0006
L
DM0006
L
00
0001
(H)
: 00 = fixed value
01 = output code (degree of match)
Register 0 (degree of
match, coordinate X,
coordinate Y
deviation) for
measurement 1
(position deviation
measurement)
09015
H
H
01
09016
D0007
L
DM0007
L
78
2678
(H)
: 9848
(D)
= 98.48%
09017
H
H
26
09020
D0008
L
DM0008
L
00
0020
(H)
: 00 = fixed value
02 = output code (X coordinate)
09021
H
H
02
09022
D0009
L
DM0009
L
92
0992
(H)
: 2450
(D)
= 245.0 (coordinate value)
09023
H
H
09
09024
D0010
L
DM0010
L
00
0005
(H)
: 00 = fixed value,05 = output code
(coordinate Y deviation)
09025
H
H
05
09026
D0011
L
DM0011
L
FA
00FA
(H)
: 250
(D)
= 25.0 (deviation value)
09027
H
H
00
09030
D0012
L
DM0012
L
01
0001
(H)
: 00 = fixed value
01 = output code (degree of match)
Register 0 (degree of
match) for
measurement 3
(degree of match
inspection)
09031
H
H
00
09032
D0013
L
DM0013
L
28
2628
(H)
: 9752
(D)
= 97.52%
09033
H
H
26
Measurement
Output
Registration
Measurement 0
Camera1
Output code 01
(degree of match)
Degree of match for register number 0
Degree of match for register number 1
to
Degree of match for register number 7
Output code 02
(coordinate X)
Coordinate X for register number 0
Coordinate X for register number 1
to
Coordinate X for register number 7
to
to
Output code 40
(numeric
calculation)
Numeric calculation result for register number 0
Numeric calculation result for register number 1
to
Numeric calculation result for register number 15
Measurement 0
Camera2
The details of the output codes and register numbers are the same as
for "MEASUREMENT 0, CAMERA1"
Measurement 1
The details of the output codes and register numbers are the same as
for "MEASUREMENT 0, CAMERA1"
Measurement 2
The details of the output codes and register numbers are the same as
for "MEASUREMENT 0, CAMERA1"
Measurement 3
The details of the output codes and register numbers are the same as
for "MEASUREMENT 0, CAMERA1"
Measurement 4
The details of the output codes and register numbers are the same as
for "MEASUREMENT 0, CAMERA1"