13-5
Color Positional Measurement
13
[1] Set the register conditions for a gray search
This paragraph describes setting procedures when the mode (see page 13-3) is set to "1-PNT SCH."
REGISTER NO.
Enter a register number. When making color
positional measurement, you can select any
register from 0 to 7 (a total of 8 registers).
COLOR DETECT
Select a reference color for color extraction from
the already registered colors (when more than
two colors are registered).
MEAS SHAPE(MDL0)
Specify reference image area and search area. Enter coordinates for upper left and lower right
corners. Inside the rectangle specified by these entries is the range of each area.
REFIMG ARE
Move the cursor to "
REFIMG ARE(MDL0)"
and press the SET key. When the SET item is
highlighted, press the SET key again to bring
up the setting screen. Specify upper left and
lower right corners of the rectangle. The setting
procedures are the same as those used for
positional deviation measurement.
See page 4-6.
1
REGISTER NO.
0 (0
〜
7)
2
COLOR DETECT
0 (0
〜
7)
3
MEAS SHAPE (MDL 0)
RECTANGLE
4
REFIMG ARE (MDL 0)
SET (224, 208)
〜
(287, 271)
5
SEARCH ARE
(MDL 0)
SET (216, 200)
〜
(295, 279)
6
REFIMG
(MDL 0)
000 (000
〜
000)
7
DETECT CRD
(MDL 0)
CENTER (255, 239)
SET
=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
COLOR F C1 BRT
REG CND
SCREEN COND SAVE DETAIL
■
REFERENCE IMG
■
DETECT CRD
MDL 0
1
UP. L
(224, 208)
2
LO. R
(287, 271)
3
MOVE
4
REFFERENCE IMG
SET
=MOVE ESC=BACK SEL=CHNG IMG TRG=FUNC
COLOR F C1 BRT
RECTANGLE
RESET RETURN
X:224 Y:208
Reference image area
Search area