7-3
BGA/CSP Inspection
7
1
WINDOW
NORMAL
2
REGISTER NO.
0(0
〜
3)
3
REGISTER EXIST
YES
REGISTER NO.
4
BIN AREA COND
MEA-CND
SCREEN COND SAVE
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
×
○ × ×
RED F C1 BRT
SET
=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
NO
YES
NORMAL
BINARY-IMG-MASK
POLYGON
1
WINDOW
BINARY-IMG-MASK
2
REGISTER NO.
0(0
〜
3)
3
REGISTER EXIST
YES
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
×
○ × ×
NO
YES
×:
No setting
Æ
Setting (display) of binary area conditions
When item
3
REGISTER
EXIST. is
set to "YES,"
a
circle is displayed.
REGISTER NO.
4
BIN AREA COND
NORMAL
0 to 3
BINARY-IMG-MASK 0 only
POLYGON
0 only
Setting the measurement conditions
WINDOW
Select a window type. On the popup
menu, move the cursor to "NORMAL,"
"BINARY-IMG-MASK," or "POLYGON,"
and press the SET key to select the item.
REGISTER NO.
Select register number to measure. Number of selectable registers varies with window
shape selected.
REGISTER EXIST
Select whether to register or not.
REGISTER NO. (
BIN AREA COND)
Register setting conditions are shown for each register number. Circles mean that
"REGISTER EXIST" has set to "YES."
NORMAL
Normal window
BINARY-IMG-
MASK
Select this item if the captured image is other than a rectangle, circle, or
ellipse. This function masks the captured image using a stored binary
image.
-
For details, see pages 3-37 to 41.
POLYGON
You can manually create any freeform polygon for the measurement area.