17-3
Fault Inspection
17
REGISTER NO.
Select register number to measure. When
making fault inspection, you can select any
register from 0 to 7 (a total of 8 registers).
MODE
Select measurement mode. Select from the
following.
MEAS OBJECT
A circle will be placed below the registered number.
How to set the register conditions
How to enter the REG-COND setting screen
There are three methods for getting to the REG-COND setting screen.
1) On the "MEAS CND" setting screen, move
the cursor to "
MEAS OBJECT" and press
the SET key. The cursor will move into the
table. Move the cursor to the "Åõ" column
and press the SET key.
Note: If you press the SET key in the "X"
column, the setting will be invalid.
2) On the "MEAS CND" setting screen, press
the TRG/BRT key to move the cursor to the
upper function menu. Select the "COND" item
and then select the "REG-COND" item and
press the SET key.
1
REGISTER NO.
0 (0
〜
7)
2
MODE
NO
REGISTER NO.
3
MEAS OBJECT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
RED F C1 BRT
MEA-CND
SCREEN COND SAVE
NO
PROXIMITY DIFFERENCE
TOTAL DIFFERENCE
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
×
× × × × × × ×
×
○ × ×
00010203040506070809101112131415
1
REGISTER NO.
0 (0
〜
7)
2
MODE
PROXIMITY DIFFERENCE
REGISTER NO.
3
MEAS OBJECT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
RED F C1 BRT
MEA-CND
SCREEN COND SAVE
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
×
○ × × × × × ×
IMG PRE-PROC
REG COND
EVALUATION
NUM-CALC
OUT
No
Does not measure
PROXIMITY
DIFFERENCE
Measures maximum
density difference
between neighbor cells.
TOTAL
DIFFERENCE
Measures maximum
density difference in the
whole area.