22-2
Communication (General Purpose Serial Interface)
22
The conditions below are what is shown when the "TRIG CCD START" is selected on the "
MEAS
INP I/F" on the "I/O CONDITIONS” selection screen.
Measurement
start
Output
selection
Serial output
Object type change
Auto
Parallel port
---
Parallel
General purpose
serial port + USB
Response output from
command code 11
Command code 55
Parallel port
None
---
Parallel
Computer link
SHARP/MITSUBISHI/
OMRON/YOKOGAWA
Parallel
General-purpose
serial port
Response output from
command code 11
Parallel
General-purpose
serial port + USB
---
Command codes 10 to 12
Command codes 10 to 12
Cate-
gory
Processing function
Code
Function
Operation lock
status
Read
50
- Read lock/unlock condition of the operation screen.
Set
51
- Set lock/unlock for the operation screen.
English or
Japanese display
Read
52
- Read the status from the English or Japanese display.
Set
53
- Enter a change on the English or Japanese display.
Object type
number
Read
54
- Read an object type number to measure when the
measurement start input is turned ON.
Set
55
- Assign an object type number to be executed when the
measurement start input is turned ON.
Image status
Read
56
- Read the image status being monitored
(Output: Through/freeze, Brightness: Full/half).
Set
57
- Change the status of the image being monitored
(Output: Through/freeze, Brightness: Full/half).
Output image
camera
Read
58
- Read the status of the camera outputting an image for
the specified object type.
Set
59
- Set the status of the camera that is outputting an image
for the specified object type.
Shutter speed
Read
5A
- Read the shutter speed setting for the specified object
type.
Set
5B
- Set shutter speed for the specified object type.
Time
Read
5C
- Read the IV-C35M's system time.
Set
5D
- Adjust the IV-C35M's system time to the time
set by the host device.
Initialize all
60
- Set all settable conditions to their initial values (global
conditions, all object type conditions, and reference
images).
White balance
67
- Adjust white balance of the image.
Self-diagnostic
68
- Check the controller for a hardware error.
Items to check: VRAM (read after write), SDRAM (read
after write), etc.
Reset
69
- Reset the controller (the same as a power reset operation).
Manual measurement
coordinates
Read
70
- Read the coordinates detected by manual measurement.
Set
71
- Set the coordinates for manual measurement.
Individual conditions