13-4
Color Positional Measurement
13
How to set the register conditions
How to enter the REG-COND setting screen
There are three methods for getting to the REG-COND setting screen.
1) On the "MEAS CND" setting screen, move
the cursor to "
MDL 0" or "
MDL 1" and
press the SET key. The cursor will move into
the table. Move the cursor to the "S" or "E"
column and press the SET key.
Note: If you press the SET key in the "X"
column, the setting will be invalid.
2) On the "MEAS CND" setting screen, press
the TRG/BRT key to move the cursor to the
upper function menu. Select the "COND" item
and then select the "REG-COND(S)" or
"REG-COND(E)" item and press the SET
key.
3) On the menu tree, move the cursor to the
"MEAS CND" item, and press the right arrow
key. The sub menu which contains the "REG-
COND(S)" and "REG-COND(E)" items will
appear. Move the cursor either of them and
press the SET key.
1
REGISTER NO.
00 (0
〜
7)
2
MODE
1P-SCH+1P-EDGE
REGISTER NO.
3
MODL 0
4
MODL 1
EXTRACT COLOR
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
COLOR F C1 BRT
MEA-CND
SCREEN COND SAVE
REG-COND (S)
REG-COND (E)
EVALUATION
NUM-CALC
OUT
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
S
S
× × × × × ×
S
E
× × × × × ×
×
×
× × × × × ×
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-CORRECT
MEAS01 (MEAS-CAM-POSI P)
MEAS CND
REG-COND (S)
REG-COND (E)
EVALUATION COND
DISTANCE&ANGLE COND
NUM-CALC
OUT-COND
MEAS02 (COLOR EVALUATION P)
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
1
REGISTER NO.
2
COLOR DETECT
3
MEAS SHAPE (MDL 0)
4
REFIMG ARE (MDL 0)
5
SEARCH ARE (MDL 0)
6
REFIMG(MDL 0)
7
DTECT CRD(MDL 0)
COLOR F C1
BRT
SELECT OBJECT TYPE COND
SET