10-5
Object Identification by Binary Conversion
10
How to set the register conditions
How to enter the REG-COND setting screen
There are three methods for getting to the REG-COND setting screen.
1) On the "MEA-CND" setting screen, move the
cursor to the "
BIN AREA COND" and
press the SET key. The cursor will move into
the table. Move the cursor to the "
○
" column
and press the SET key.
Note: If you press the SET key in the "X"
column, the setting will be invalid.
2) On the "MEA-CND" setting screen, press the
TRG/BRT key to move the cursor to the upper
function menu. Select the "COND" item and
then select the "REG COND" item and press
the SET key.
3) On the menu tree, move the cursor to the
"MEAS CND" item, and press the right arrow
key. The sub menu which contains the "REG
COND" item will appear. Move the cursor to
this item and press the SET key.
Set the register conditions
REGISTER NO.
The currently selected register number is
displayed.
If you want to set the measurement
conditions for a different register number,
press the SET key to highlight the register
number currently selected. Then press the up
and down arrow keys to select the register
number whose measurement conditions you
want to set. Press the SET key to confirm
your selection.
Note: When the "BINARY-IMG-MASK" or the
"POLYGON" is
selected at "
WINDOW" on the "MEA-CND" screen, the "
REGISTER
NO." line will not be displayed and the other item numbers are decrement
by one since the register number for "BINARY-IMG-MASK" and
"POLYGON" is fixed.
1
REGISTER NO.
2
MEAS SHAPE
3
MEAS AREA
4
THRESHOLD
5
INVERT B/W
COLOR F C1 BRT
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-DEVIATION
MEAS01(LABEL-BIN-OBJ F)
IMG PRE-PROC
MEAS CND
REG-COND
EVALUATION COND
DISTANCE&ANGLE COND
NUM-CALC
OUT-COND
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
+
+
1
MEAS SHAPE
2
MEAS AREA
3
THRESHOLD
4
INVERT B/W
MEA-CND
1
REGISTER NO.
00(0〜15)
2
MEAS SHAPE
RECTANGLE
3
MEAS AREA
SET (224,208)
〜
(287,271)
4
THRESHOLD
SET [U.LM255 L.LM100 (0~255)]
5
INVERT B/W
NO
RED F C1 BRT
REG COND
SCREEN COND SAVE DETAIL
NO
YES
RECTANGLE
CIRCLE
ELLIPSE
IMG PRE-PROC
REG COND
EVALUATION
DST&ANGL
NUM-CALC
OUT
MEA-CND
SCREEN COND SAVE
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
× × ×
○
RED F C1 BRT
1
MEAS GRAV CENTER
NO
2
WINDOW
NORMAL
3
REGISTER NO.
0(0
〜
3)
4
REGISTER EXIST
YES
5
LABEL ORDER
SCAN-ORDER
6
AX.ANGL
NO
7
FILT
NO
8
CIRC-L
NO
9
MID-PNT
NO
REGISTER NO.
0
BIN AREA COND