Lead Inspection
6-3
6
1
REGISTER NO.
00(0
〜
15)
2
REGISTER EXIST
YES
3
DTECT PRECISION STANDARD
REGISTER NO.
4
MEAS OBJECT
LEAD LENGTH
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
×
○ × × × × × × × × × × × × × ×
×
× × × × × × × × × × × × × × ×
RED F C1 BRT
MEAS CND
SCREEN
COND
SAVE
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
STANDARD
HIGH
NO
YES
1
REGISTER NO.
00(0
〜
15)
2
REGISTER EXIST
YES
3
DTECT PRECISION STANDARD
REGISTER NO.
4
MEAS OBJECT
LEAD LENGTH
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
×
○ × × × × × × × × × × × × × ×
×
× × × × × × × × × × × × × × ×
RED F C1 BRT
MEAS CND
SCREEN
COND
SAVE
SEL=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
IMG PRE-PROC
REG-COND
EVALUATION
NUM-CALC
OUT
Setting the measurement conditions
REGISTER NO.
16 registers are available for the lead
inspection (Registers 0 to 15).
If you want to set the measurement
conditions for a different register number,
press the SET key to highlight the
register number currently selected. Then
press the up and down arrow keys to
select the register number whose
measurement conditions you want to set.
Press the SET key to confirm your
selection.
REGISTER EXIST
Select whether to register or not.
DTECT PRECISION
Select detection precision. You can
select one of two levels (standard/high),
according to your conditions, the desired
precision level for detection results, and the detection speed.
For details, see page 3-20.
REGISTER NO. (
MEAS OBJECT, LEAD LENGTH)
Register setting conditions are shown for each register number. Circles mean that
"REGISTER NO." has set to "YES."
How to set the register conditions
How to enter the REG-COND setting screen
There are three methods for getting to the REG-COND setting screen.
1) On the MEAS CND setting screen, move
the cursor to "
MEAS OBJECT" and
press the SET key. The cursor will move
into the table. Move the cursor to the "
○
"
column and press the SET key.
Note: If you press the SET key in the "X"
column, the setting will be invalid.
2) On the "MEAS CND" setting screen, press
the TRG/BRT key to move the cursor to the
upper function menu. Select the "COND"
item and then select the "REG-COND" item
and press the SET key.
When item "
2
REGISTER EXIST" has set "YES," a
circle is displayed.
On the "REG COND" screen, when the "
7
EXTENSION
MEAS" is set to "LEAD-LENGTH," or "BALL-WIDTH," a
circle is displayed.
See
7
and
8
on page 6-6.
REGISTER NO.
4
MEAS OBJECT
LEAD LENGTH
Æ
Setting (display) of items to be inspected
X : No setting
00 01 02
○ ○ ×
○ × ×