21-5
Setting the Input/Output Conditions
21
21-2 Measurement start input and result output settings
The combinations of various settings for item "
MEAS INP I/F," item "
START CCD SAMPL," and
item "
(
)OUT I/F (PARAL.)" on the "I/O CONDITIONS" screen (page 21-1 to 4) are explained
below.
The time required to change object types is calculated differently according to the type of
measurement start input I/O, as follows:
Measurement start input I/F
Time to change object type
Parallel
Included in the measurement execution time
General-purpose serial
Not included in the measurement execution time
CCD trigger
Not included in the measurement execution time
Object type select switch (object type input)
- Parallel
Measurement
start input interface
Result output
Parallel
→
(1)
Computer link/parallel
→
(2)
General purpose serial/parallel
→
(3)
- General purpose
serial
- CCD trigger
General purpose serial/parallel
→
(4)
Parallel
(Parallel)
Parallel
→
(5)
Computer link/parallel
→
(6)
General purpose serial/parallel
→
(7)
General purpose
serial
(General purpose
serial)
General purpose serial/parallel
→
(8)
Auto
Parallel
General purpose
serial
Parallel
→
(9)
General purpose serial/parallel
→
(10)
Start sampling
Object type
change
Result output
Controller
Input terminal (model number)
IV-C35M
X1 to X5 (0 to 31: 32 object types)