7-4
BGA/CSP Inspection
7
1
REGISTER NO.
0(0〜3)
2
MEAS SHAPE
RECTANGLE
3
MEAS AREA
SET (224,208)
〜
(287,271)
4
THRESHOLD
SET [U.LM255 L.LM100 (0~255)]
5
INVERT B/W
NO
6
NUM. OF DTECT
X00 Y00 (0~64)
RED F C1 BRT
REG COND
SCREEN COND SAVE DETAIL
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
RECTANGLE
CIRCLE
ELLIPSE
NO
YES
1
REGISTER NO.
2
MEAS SHAPE
3
MEAS AREA
4
THRESHOLD
5
INVERT B/W
6
NUM. OF DTECT
COLOR F C1 BRT
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE01
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-DEVIATION
MEAS01(INSPECT-BGA/CSP)
IMG PRE-PROC
MEAS CND
REG-COND
EVALUATION COND
DISTANCE&ANGLE COND
NUM-CALC
OUT-COND
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
+
+
+
+
How to set the register conditions
How to enter the REG-COND setting screen
There are three methods for getting to the REG-COND setting screen.
1) On the "MEA-CND" setting screen, move
the cursor to the "
(or
) BIN AREA
COND" and press the SET key. The
cursor will move into the table. Move the
cursor to the "
○
" column and press the
SET key.
Note: If you press the SET key in the "X"
column, the setting will be invalid.
2) On the "MEA-CND" setting screen, press the TRG/BRT key to move the cursor to the upper
function menu. Select the "COND" item and then select the "REG COND" item and press the
SET key.
3) On the menu tree, move the cursor to the
"MEAS CND" item, and press the right
arrow key. The sub menu which contains
the "REG COND" item will appear. Move
the cursor to this item and press the SET
key.
Set the register conditions
REGISTER NO.
The currently selected register number is
displayed.
If you want to set the measurement
conditions for a different register number,
press the SET key to highlight the register
number currently selected. Then press the
up and down arrow keys to select the
register number whose measurement
conditions you want to set. Press the SET
key to confirm your selection.
1
WINDOW
NORMAL
2
REGISTER NO.
0(0
〜
3)
3
REGISTER EXIST
YES
REGISTER NO.
4
BIN AREA COND
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
×
○ × ×
RED F C1 BRT
MEA-CND
SCREEN COND SAVE
IMG PRE-PROC
REG COND
EVALUATION
NUM-CALC
OUT