13-10
Color Positional Measurement
13
Numeric calculation setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using the
left and right arrow keys. Press the SET key to show the popup menu. Select "NUM-CALC" from the
popup menu.
- Select "NUM-CALC" on the menu tree.
See "Chapter 19: Numerical calculations."
Output condition setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using the
left and right arrow keys. Press the SET key to display the popup menu. Select "OUT" from the popup
menu.
- Select "OUT-COND" on the menu tree.
See "Chapter 21: Setting the Input/Output Conditions.
Display the measurement results
Return to the operation screen and press the TRG/BRT key. The measurement results will be
displayed on the screen.
COLOR F C1 BRT
V*.**
(TYPE00)
OK
MEAS XXXXms 2002-01-01 10:30
MEASURE 0 CAM1 MEAS-COLOR-POSI
REGISTER NO(0~7)
X0=176.0 OK
Y0=322.0 OK
x0=+000.0 OK
y0=+000.0 OK
M0=+10000 OK
B0=+001.7 OK
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
X0~7
□□□□□□□□
Y0~7
□□□□□□□□
READY
■
●
1P-SCH
Amount of angular deviation*
Registration number
Degree of match with the
reference image for model 0
Detection coordinates in the
reference image for model 0
Amount of deviation from the
reference image for model 0
* When the "
4
DTECT ANGL" is
set to "YES," angle is displayed.
COLOR F C1 BRT
V*.**
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
X0~7
□□□□□□□□
Y0~7
□□□□□□□□
READY
■
●
1P-EDGE
Degree of match with the
reference image for model 1
Registration number
Detection coordinates in the
reference image for model 1
Amount of deviation from the
reference image for model 1
(TYPE00)
OK
MEAS XXXXms 2002-01-01 10:30
MEASURE 0 CAM1 MEAS-COLOR-POSI
REGISTER NO(0~7)
X1=534.0 OK
Y1=480.0 OK
x1=+001.0 OK
y1=+001.0 OK
K1=1
B0=