4-10
Positional Deviation Measurement
4
Set the evaluation conditions
How to move to the evaluation condition setting screen
There are two methods for getting to the evaluation condition setting screen.
1) Select "COND" in the upper function menu on
the MEAS COND (or REG COND) screen
and press the SET key. Select
"EVALUATION" on the pop up menu to go to
the EVALUAT COND screen.
2) Move the cursor to the "EVALUATION COND"
item on the Menu tree screen and press the
SET key.
The "EVALUAT COND" (evaluation conditions)
screen will appear.
For details about the evaluation conditions, see
page 3-28.
1
REGISTER NO.
2
CONDITION SET
3
X COORD.(MDL0)
4
Y COORD.(MDL0)
5
x DEVAITE(MDL0)
6
y DEVAITE(MDL0)
7
MATCH LVL(MDL0)
8
TEST
F C1 BRT
SELECT OBJECT TYPE COND COLOR
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0(POSI-DEVIATION F)
IMG PRE-PROC
MEAS CND
REG-COND(S)
REG-COND(E)
EVALUATION COND
DISTANCE&ANGLE COND
NUM-CALC
OUT-COND
POSI-CORRECT
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
+
+
+
REGISTER NO.
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
×
S
× × × × × ×
× × × × × × × ×
F C1 BRT
MEAS CND
SCREEN
COND
SAVE BLUE
SET=SELECT A MENU FOR ESC=BACK SEL=CHNG IMG TRG=FUNC
1
DTECT PRECISION STANDARD
2
REGISTER NO.
0(0
〜
7)
3
MODE
1P-SCH
4
DTECT ANGL
NO
5
ANGLE UNIT
6
MDL 0
7
MDL 1
IMG PRE-PROC
REG-COND(S)
REG-COND(E)
EVALUATION
DST&ANGL
NUM-CALC
OUT
1
REGISTER NO.
0(0~7)
[TEST RESULT]
[OUTPUT]
2
CONDITION SET
AUTO(–10%)
3
X COORD.(MDL0)
000.0~511.0
X0=
NO
4
Y COORD.(MDL0)
000.0~479.0
Y0=
NO
5
x DEVAITE(MDL0)
-511.0~+511.0
x0=
NO
6
y DEVAITE(MDL0)
-479.0~+479.0
y0=
NO
7
MATCH LVL(MDL0)
-10000~+10000 M0=
NO
8
TEST
EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
F C1 BRT
EVALUAT COND SCREEN COND SAVE EDIT SEL BLUE