1-22
Setting and Operating Outline
1
(2) Displaying images on the NG image display screen
When the IV-C35M is used, move the cursor to the menu bar "SCREEN-CHG" on the operation main
screen (page 1-10) and press the SET key. Select the "NG-IMG-DISP" from popup menu. The screen
will change to the NG image display. When the measurement stops, the NG image will be displayed.
- To display NG images while measuring, display them on the operation main screen.
Note: Please be aware of the following.
1. Change the image display mode in the upper right of the screen to "F" (freeze image) by
pressing the SET key.
2. You cannot measure objects while an NG image is being displayed on the NG image
display screen.
Display the NG image number and
the number of NG images that
have been registered.
The NG image number can be
selected by selecting "NEXT-NG"
on the menu bar.
Displays the date and time the NG
image was captured.
Example: 2000-10-01 10:25
October 1st, 2000, AM
10:25.
Menu bar
When "CAM1&2" is selected on the "
MONITOR OUTPUT" line (TYPE RUN COND
menu), the camera numbers (CH) will be displayed on the screen next to the images from
those cameras.
Menu bar
Details
CHG-MEA
(change measurement)
Change the evaluation result display for the measurement
numbers using the up and down keys.
(MEASURE0 CAM1 -> MEASURE0 CAM2 -> MEASUREMENT1 ->
MEASUREMENT2 -> MEASUREMENT3 -> MEASUREMENT4 ->)
COND-CHG
(change measurement
condition)
Change the operation menu using the up and down keys. "Display NG
image" -> change evaluation conditions
- The operating screen display must be set to "YES."
-
See page 2-9.
- For information about the evaluation condition change screen,
see page 2-11.
- On the evaluation condition change screen, press the SET key.
The cursor will move to the setting change screen.
CHNG-REG
(change register)
Change the measurement result display of the registered numbers in
the measurement program using the up and down keys.
NEXT-NG
(change NG image)
Change the registered number for the NG image being displayed
using the up and down keys.
-
See the next page.
RE-EXAM
(replay)
Replay the measurements made on the NG image selected with
"NEXT-NG", by pressing the SET key.
DEL NG
(delete NG image)
Press the SET key. Only the NG image selected with "NEXT-NG" will
be deleted.
DEL ALL N (delete all
NG images)
Press the SET key. All the registered NG images will be deleted.
OPS-MENU
Press the SET key, the screen will return to the operation main screen.
(
TYPE00
)
V*.**
MEAS
××××
ms
2001-10-14 10:38
X0~7
□□□□□□□□
Y0~7
□□□□□□□□
READY
■ X:360 Y:350
MNU-CHG CHG-MEA COND-CHG CHNG-REG NEXT-NG RE-EXAM DEL NG
MEASURE 0 CAM1 POSI-DEVIATION
OK
*2
Displayed when the menu is changed.
MNU-CHG OPS-MENU DEL ALL NG
4
COLOR F CH DRK
○
NG-IMG
0 (1P)
2001-11-01 10:25
1
2
3