14-8
Point Measurement
14
The "EVALUAT COND" (evaluation conditions) screen will appear.
For details about the evaluation conditions, see page 3-28.
Numeric calculation setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using
the left and right arrow keys. Press the SET key to show the popup menu. Select "NUM-CALC" from
the popup menu.
- Select "NUM-CALC" on the menu tree.
See "Chapter 19: Numerical calculation."
Output condition setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using
the left and right arrow keys. Press the SET key to display the popup menu. Select "OUT" from the
popup menu.
- Select "OUT-COND" on the menu tree.
See "Chapter 21: Setting the Input/Output Conditions."
・
When MODE has been set to "BINARY"
・
When MODE has been set to "AVG-GRAYS"
1
PAGE CHNG
˚
[TEST RESULT]
[OUTPUT]
2
P000
WHITE
OK
NO
3
P001
WHITE
OK
NO
4
P002
WHITE
OK
NO
5
P003
WHITE
OK
NO
6
P004
WHITE
OK
NO
7
P005
8
P006
9
P007
0
TEST
EXEC (WITH-POSI.ADJ WITHOUT-POSI.ADJ)
EVALUAT COND SCREEN COND SAVE EDIT SEL RED F C1 DRK
①
PAGE CHNG
[TEST RESULT]
[OUTPUT]
②
CONDITION SET REST(
±
10%)
③
P000
200~210
200
OK
NO
④
P001
200~210
200
OK
NO
⑤
P002
200~210
200
OK
NO
⑥
P003
200~210
200
OK
NO
⑦
P004
200~210
200
OK
NO
⑧
P005
⑨
P006
⑩
P007
⑪
TEST
EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
EVALUAT COND SCREEN COND SAVE EDIT SEL RED F C1 DRK
Not displayed for unregistered point numbers.
You can set the output destinations using the up
and down keys. (NO, Y0 to Y7, C000 to C127)
Acceptance (OK/NG) criteria
WHITE: Acceptable when a majority of the inspected
pixels are white.
BLACK: Acceptable when a majority of the inspected
pixels are black.
Ex.: When the point to be inspected is 8 X 8 (64 pixels)
and WHITE is specified, if 33 white pixels are
detected, the point is accepted.
You can set the output destinations using the up
and down keys. (NO, Y0 to Y7, C000 to C127)
Average light level for each point