TPS “OUT OF RANGE” Fault
It is caused by the sensor reading going out of its allowable range. This fault can occur during the whole
range of movement of the throttle.
To diagnose this fully, it is recommended to operate the throttle through its full range. It is also recom-
mended to release the throttle quickly as this may also show up a fault that is intermittent.
TPS “ADAPTATION FAILURE” Fault
It is caused by the idle position moving out of an acceptable range.
POSSIBLE CAUSES
RESULT
ACTION
Check if wrong connector is connected to TPS.
Yes
• Fix.
Check if sensor is loose.
Yes
• Fix and reset closed TPS.
Inspect sensor for damage or corrosion.
Yes
• Replace and reset closed TPS.
Inspect wiring (voltage test).
Failed
• Repair.
Inspect wiring and sensor (resistance test).
Failed
• If bad wiring, repair.
• If bad TPS, replace and reset closed TPS.
Test sensor operation (wear test).
Failed
• Replace and reset closed TPS.
POSSIBLE CAUSES
RESULT
ACTION
Sensor has been replaced and TPS closed
position not reset.
Yes
• Reset closed TPS.
Throttle body has been replaced and TPS
closed position not reset.
Yes
• Reset closed TPS.
MPEM has been replaced and TPS closed
position not reset.
Yes
• Reset closed TPS.
Throttle cable too tight.
Yes
• Fix and reset closed TPS.
Sensor is loose.
Yes
• Fix and reset closed TPS.
Throttle bracket is loose.
Yes
• Fix and reset closed TPS.
Idle screw or synchronization screw worn
or loose.
Yes
• Fix and reset closed TPS.
www.SeaDooManuals.net
Содержание GTX 4-TEC 5573 2002
Страница 1: ...www SeaDooManuals net ...
Страница 2: ...2002 Shop Manual Volume 2 GTX DI GTX 4 TEC www SeaDooManuals net ...
Страница 501: ...GTX DI MODEL www SeaDooManuals net ...
Страница 502: ...F18Z0P MODEL GTX DI 2002 12 VOLTS DISTRIBUTION www SeaDooManuals net ...
Страница 503: ...GTX 4 TEC MODEL www SeaDooManuals net ...
Страница 505: ...www SeaDooManuals net ...