8000m Series
- 78 -
F4.03
V/F frequency 1
Factory Setting
5.00Hz
Setting Options
0.00Hz
~
F4.05
F4.04
V/F voltage 1
Factory Setting
12.0%
Setting Options
0.0%
~
100.0%
F4.05
V/F frequency 2
Factory Setting
10.00Hz
Setting Options
F4.03
~
F4.07
F4.06
V/F voltage 2
Factory Setting
26.0%
Setting Options
0.0%
~
100.0%
F4.07
V/F frequency 3
Factory Setting
20.00Hz
Setting Options
F4.05
~
motor rated frequency
F4.08
V/F voltage 3
Factory Setting
45.0%
Setting Options
0.0%
~
100.0%
The 6 parameters of F4.03
~
F4.08 define multistage V/F curve.
The setting values of V/F curves are determined by the load characteristics of the
electric motor.
Note: the relationships of the three voltage and frequency must meet: V1<V2<V3
,
F1<F2<F3. When the frequency is low, high voltage setting may cause over-heating
of motor or even burn the motor, and the VFD may lose speed because of
over-current or get into over-current protection.
V1
~
V3: Voltage percentage of 1
~
3 multistage V/F curve
F1
~
F3: frequency point of 1
~
3 multistage V/F curve
Fb: rated motor frequency F2.02
This is effective for V/F control. Setting this parameter can make up the speed
F4.09
Coefficient of V/F Slip compensation
Factory Setting
0.00%
Setting Options
0.0%
~
200.0%
Содержание 8000m Series
Страница 1: ...8000m Series Compact AC Drive User Manual Version Code 8000m E 602000600 1705...
Страница 11: ...8000m Series 10 Chapter 1 Introduction to the 8000m series VFD 1 1 Model Description 1 2 Namplate Example...
Страница 20: ...8000m Series 19 2 1 4 Electric Elements and Material Peripheral Electric Elements Connection Diagram...
Страница 150: ...8000m Series 149 8 8 Data Address Table of Function Code...
Страница 151: ...8000m Series 150...
Страница 152: ...8000m Series 151...