![SAJ 8000m Series Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/saj/8000m-series/8000m-series_user-manual_3527063043.webp)
8000m Series
- 42 -
Function
Code
Function
Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
F6.10~F
6.13
Reserved
F6.14
User defined
output
variability option
(EX)
0:Running frequency
1:Setting frequency
2:DC bus voltage
3:Output current
4:Output voltage
5:Sign of start and stop status
6:Sign of control status
7:Counter value
8:Counting meter value
9:Inverter module temperature
10:AVI input value
11:Reserved
F6.15
Comparison
method of user
defined output
Units digit: comparison test
method
0: Equal (EX==X1)
1: Equal or greater than
2: Equal or less than
3: Interval comparison
(X1
≤
EX
≤
X2)
4:Units digit test (EX&X1=X2)
Tens digit : output method
0: False value output
1: Real value output
0
○
F6.16
User defined
output dead zone
0~65535
0
○
F6.17
Output comparison
value X1
0~65535
0
○
F6.18
Output comparison
value X2
0~65535
0
○
F7 Group: Display Interface Parameters
F7.00 User
password
0~9999
0
○
Содержание 8000m Series
Страница 1: ...8000m Series Compact AC Drive User Manual Version Code 8000m E 602000600 1705...
Страница 11: ...8000m Series 10 Chapter 1 Introduction to the 8000m series VFD 1 1 Model Description 1 2 Namplate Example...
Страница 20: ...8000m Series 19 2 1 4 Electric Elements and Material Peripheral Electric Elements Connection Diagram...
Страница 150: ...8000m Series 149 8 8 Data Address Table of Function Code...
Страница 151: ...8000m Series 150...
Страница 152: ...8000m Series 151...