8000m Series
- 93 -
Setting
value
Function
Instructions
reach the FDT level, the output becomes
ON.
11
Accumulative
running time reached
If the accumulative running time of the
VFD exceeds the time set in F8.17, the
output becomes ON.
12
PLC cycle
completed
When simple PLC operation completes one
cycle, the output becomes on as a pulse
signal with width of 250 ms.
13
VFD overload
pre-alarm
The output becomes ON after the pre-alarm
time as the VFD reaching pre-alarm
threshold value.
14
User Customized
Output
Users can customize the output function,
refer to F6.14~f6.18
15
Running frequency
detection
When the running frequency is less or equal
to the setting of F8.22, or is larger or equal
to the setting of F8.23, the output becomes
ON; When the output frequency is between
F8.22 and F8.23, the output becomes OFF.
16
Terminal input delay
output
As a multifunction digital input is set as the
function of Terminal Input Delay Output, if
the time-lasting exceeds the time setting of
F8.21 after input is closed, the output
becomes ON.
17 VFD
stand-by
When the VFD is Power on and is in STOP
status without any fault occurring (include
LU fault, the output becomes ON; After the
VFD turns into running, or there is a fault,
the output becomes OFF.
Содержание 8000m Series
Страница 1: ...8000m Series Compact AC Drive User Manual Version Code 8000m E 602000600 1705...
Страница 11: ...8000m Series 10 Chapter 1 Introduction to the 8000m series VFD 1 1 Model Description 1 2 Namplate Example...
Страница 20: ...8000m Series 19 2 1 4 Electric Elements and Material Peripheral Electric Elements Connection Diagram...
Страница 150: ...8000m Series 149 8 8 Data Address Table of Function Code...
Страница 151: ...8000m Series 150...
Страница 152: ...8000m Series 151...