Deceleration time 1 means the needed time T2 that the VFD decelerate from the
Max. output frequency(F0.10)to 0Hz.
See the diagram below:
Figure xx Sketch Map of Acceleration and Deceleration Time
Note: The difference between the actual acceleration/deceleration time and the set
acceleration/ deceleration time.
Totally 4 groups of acceleration and deceleration time are optional.
Group 1: F0.18, F0.19;
Group 2: F8.03, F8.04
Group 3: F8.05, F8.06
Group 4: F8.07, F8.08.
The acceleration and deceleration time can be selected through the multi-function
digital input terminals (F5.00
~
F5.03).
F0.20
Default Setting Restoring
Factory Setting
0
Setting
Options
0 No
operation
1
Restore to factory setting