![SAJ 8000m Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/saj/8000m-series/8000m-series_user-manual_3527063012.webp)
8000m Series
- 11 -
1.3 Model Table
1.4 Specifications
Control Characteristics
Control Mode
V/F control
Starting Torque
0.5Hz 100%
Speed Control Range
1:20
Precision of Speed
Regulation
±
1.0%
Overload Capacities
Model G: 60 seconds at 150% rated current; one second at 180%
rated current.
V/F Curve Options
Three options: Linear, Square and Multipoint.
DC Injection Braking
Function
Braking start frequency: 0.00~Max. frequency limit;
Braking time:0.1~50.0s;
Braking current:0 ~150% of rated current(model G);
Braking start waiting time:0.0~50.0s.
Jog Operation
Jog frequency range: 0.00-max.frequency;
Accel./Decel. time of jog operation:0.1~3600s.
Accel./Decel. Time
Accel./Decel. time range:0.1~3600s
Torque Boosting
Manual setting:0.1~30.0%; Automatic setting:0.0%
Drive Model
Rated Output
Power kW
Rated Input
Current A
Rated Output
Current A
Motor Power
kW
Single-phase 220V±15%
8000m-2SR4GH
0.4
4.5
2.4
0.4
8000m-2SR75GH
0.75
8.2
4.5
0.75
8000m-2S1R5GH
1.5
14.2
7
1.5
8000m-2S2R2GH
2.2
23
10
2.2
Three-phase 380V±15%
8000m-4TR75GH
0.75
3.4
2.5
0.75
8000m-4T1R5GH
1.5
5
3.7
1.5
8000m-4T2R2GH
2.2
5.8
5.0
2.2
Содержание 8000m Series
Страница 1: ...8000m Series Compact AC Drive User Manual Version Code 8000m E 602000600 1705...
Страница 11: ...8000m Series 10 Chapter 1 Introduction to the 8000m series VFD 1 1 Model Description 1 2 Namplate Example...
Страница 20: ...8000m Series 19 2 1 4 Electric Elements and Material Peripheral Electric Elements Connection Diagram...
Страница 150: ...8000m Series 149 8 8 Data Address Table of Function Code...
Страница 151: ...8000m Series 150...
Страница 152: ...8000m Series 151...