Protocol data unit
Data length(bytes)
Range
Command 1
03H
Returned byte number
2
2*Read number
Data content
2
If the operation fails, the VFD will reply a message formed by failure command
and error code. The failure command is (Command
+
0x80). The error code
indicates the reason of the error; see the table below.
Code
Error
Error content
01H Illegal
Command
The command from master cannot be executed. The reason
maybe:
1. This command is only for new version and this version
cannot realize.
2. Slave is in fault and cannot execute it.
02H
Illegal data
address
Some of the operation addresses are invalid or not allowed to
access.
03H Illegal
value
When there are invalid data in the message framed received
by slave.
Note: This error code does not indicate the data value to write
exceed the range, but indicate the message frame is an illegal
frame.
06H
Slave busy
VFD is Busy (EEPROM is storing).
10H Password
error
The password written to the password check address is not the
same as the password set by F7.00.
11H
Checksum error
The CRC (RTU mode) check not passed.
12H
Written no
allowed
It only happen in write command, the reason maybe:
1. The data to write exceed the range of according parameter.
2. The parameter should not be modified now.
3. The terminal has already been used.
13H System
locked
When password protection take effect and user does not
unlock it, write/read the function parameter will return this
error.
Содержание 8000m Series
Страница 1: ...8000m Series Compact AC Drive User Manual Version Code 8000m E 602000600 1705...
Страница 11: ...8000m Series 10 Chapter 1 Introduction to the 8000m series VFD 1 1 Model Description 1 2 Namplate Example...
Страница 20: ...8000m Series 19 2 1 4 Electric Elements and Material Peripheral Electric Elements Connection Diagram...
Страница 150: ...8000m Series 149 8 8 Data Address Table of Function Code...
Страница 151: ...8000m Series 150...
Страница 152: ...8000m Series 151...