Roller perimeter for fixed
length control
Factory Setting
100cm
Setting Options
0~9999cm
Set roller perimeter which refers to 1 pulse of discrete signal per round to the
multi-function digital input terminal of VFD.
Length counting displaying by VFD=Roller perimeter
×
accumulation of pulses.
FB.06
Fixed length setting
Factory Setting
1000m
Setting Options
0~9999m
Set the target fixed length, as the displaying length reached this setting or 9999m,
it means the fixed length control is over and the VFD will display “FULL” and
stop. To clear the accumulated length value and fault please press STOP key.
FB.07
Clear length value
Factory
Setting
0
Setting Options
0 No
operation
1 Clear
This parameter is for the operation of clearing current length value, and after
clearing operation the parameter will be reset to 0 automatically.
FB.08
Counter value setting
Factory Setting
0
Setting Options
FB.09~9999
FB.09
Designated counter value
Factory Setting
0
Setting Options
0~FB.08
FB.10
Length unit selection
Factory Setting
0
Setting Options
0
Actual counting length =
displayed length* 1m
1
Actual counting length=
displayed length* 10m
Содержание 8000m Series
Страница 1: ...8000m Series Compact AC Drive User Manual Version Code 8000m E 602000600 1705...
Страница 11: ...8000m Series 10 Chapter 1 Introduction to the 8000m series VFD 1 1 Model Description 1 2 Namplate Example...
Страница 20: ...8000m Series 19 2 1 4 Electric Elements and Material Peripheral Electric Elements Connection Diagram...
Страница 150: ...8000m Series 149 8 8 Data Address Table of Function Code...
Страница 151: ...8000m Series 150...
Страница 152: ...8000m Series 151...