8000m Series
- 38 -
Function
Code
Function
Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
F5 Group: Input Terminals Parameters
F5.00
M1 terminal
function
0:Invalid 1:Forward run (FWD)
2:Reverse run (REV)
3:3-wire control
4:Forward jog run (FJOG)
5:Reverse jog run (RJOG)
6: Coast to stop
7: Fault reset (RESET)
8: Pause running
9: External fault input N. O.
10: UP Key command
11: DOWN Key command
12: Clear UP/DOWN setting
13: Frequency setting source
switch between X and Y
14: Frequency setting source
switch between X and (X+Y)
15: Frequency setting source
switch between Y and (X+Y)
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
18: Multi-step speed terminal 3
19: Multi-step speed terminal 4
20: Multi-step speed pause
21: Acceleration/deceleration
time selection terminal 1
22: Acceleration/deceleration
time selection terminal 2
23: Restart simple PLC af ter
pause
1
●
F5.01
M2 terminal
function
2
●
F5.02
M3 terminal
function
7
●
F5.03
M4 terminal
function
0
●