8 Using 3D
84
Basic User Manual
−
If is highlighted, adjust the sample line by positioning the anchor with the trackball.
7. Select the
Menu
key and set
User Mode
,
Render Mode
,
Image Quality
,
Sweep Angle
or
Stabilization
in the
pop-up menu.
−
Select
User Mode
, rotate the
Menu
key or press the ← or → key to select a user mode.
−
Select
Stabilization
, rotate the
Menu
key or press the ← or → key to enable or disable the stabilization.
−
Select
Image Quality
, rotate the
Menu
key or press the ← or → key to adjust quality of images.
−
Select
Sweep Angle
, rotate the
Menu
key or press the ← or → key to adjust the sweep angle of probe.
8. Select the
Freeze
key to display the 3D imaging.
The imaging area of the screen is divided into 3 reference images and a 3D image by default.
FPS 47
D/G 3/1
GN 255
I/P 3/30
PWR 70
FRQ 3-4.8
D 16.5cm
Angle 55
Map 4
Quality H
Surface
View A
A
B
C 3D
View B
View C
3D Image
Figure 8-2 3D Imaging Screen
As the above figure shows,
−
View A on the top left shows the image on the X-axis.
−
View B on the top right shows the image on the Y-axis.
−
View C on the bottom left shows the image on the Z-axis.
−
The image on the bottom right shows the 3D image.
−
Select the
Freeze
key again to display the 4D imaging.
−
Select
Full Disp�2D
by pressing the corresponding function key to return to the 3D inactivated mode.
−
Select the
3D/4D
key on the control panel to exit the 3D imaging mode and return to a real time B-mode.
8�2
Working with 3D Images
You can review, optimize or save 3D images.
8�2�1
Adjusting ROI
You can crop the 3D image by adjusting the ROI on the reference images to remove areas outside from the area of
interest. This feature is suitable for cropping regular reviews.
Perform the following steps to crop a review.
1. Select the
T-ball
key to activate the cursor.
2. Move the cursor to the image of View A, View B or View C by using the trackball, and select the
Set
or
Update
key to choose the desired reference image.
3. Crop the image of View A, View B or View C, as shown in Figure 8-3.
Содержание EVUS 8
Страница 1: ...C d Rev 02 77000001436 EVUS 8 OWNER S MANUAL English...
Страница 10: ...This page is intentionally left blank...
Страница 18: ...This page is intentionally left blank...
Страница 62: ...This page is intentionally left blank...
Страница 88: ...This page is intentionally left blank...
Страница 92: ...This page is intentionally left blank...
Страница 112: ...This page is intentionally left blank...
Страница 122: ...This page is intentionally left blank...
Страница 149: ...139 Appendix E Acoustic Output Data Please refer to Section 4 9 2 Acoustic Output...
Страница 150: ...NUM REG ANVISA 10069210070 www saevo com br...