S2600E CLI Reference Guide Chapter 2 QoS Configuration Command
Command
mode
Interface configuration mode.
Usage
guidelines
The member port joined the virtual group must be physical
port or Aggregate Port. The virtual group member ports
must be in the same line card(for the chassis-shaped
switch) or in the same switch(for the box-shaped switch). If
the line card or switch has 48 ports, then all member ports
shall be distributed on the former 24 ports or the latter 24
ports.
Examples
The following example sets the interface gigabitEthernet
1/3 as the member of virtual group 3:
Ruijie(config)#
interface gigabitethernet
1/3
Ruijie(config-if)#
virtual-group
3
Command
Description
Related
commands
show
virtual-group
Show the virtual-group settings.
Platform
description
The software version must be RGOS10.1 and higher.
2.3
Showing Related Command
2.3.1
show class-map
Use this command to show the information of class maps.
show class-map
[
class -name
]
Parameter
Description
Parameter
description
class-name
Name of the class map
Default
configuration
All class maps are shown by default.
Содержание RG-S2600E Series
Страница 1: ...CLI Reference Guide RG S2600E Series Switch RGOS 10 4 3 p1 1...
Страница 5: ...Basic Configuration...
Страница 83: ...Ethernet Switching...
Страница 240: ...IPApplication...
Страница 263: ...S2600E P CLI Reference Guide Chapter 1 IP Address Configuration Commands Platform description...
Страница 317: ...S2600E P CLI Reference Guide Chapter 5 DHCP Relay Configuration Commands Platform description...
Страница 335: ...Network Management and Monitoring...
Страница 361: ...S2600E CLI Reference Guide Chapter 1 SNMP Configuration Command Platform description Supported by switches only...
Страница 408: ...S2600E CLI Reference Guide Chapter 5 SPAN Configuration Commands...
Страница 415: ...S2600E CLI Reference Guide Chapter 6 RSPAN Configuration Commands Platform description N A...
Страница 416: ...Multicast Commands...
Страница 449: ...S2600E P CLI Reference Guide Chapter 1 IGMP Snooping Commands Example3 Example4...
Страница 450: ...S2600E P CLI Reference Guide Chapter 1 IGMP Snooping Commands...
Страница 477: ...Security...
Страница 526: ...S2600E CLI Reference Guide Chapter 1 AAA Configuration Commands Platform description Supported by switch products only...
Страница 656: ...S2600E CLI Reference Guide Chapter 5 Web Authentication Configuration Commands Configuration Example...
Страница 735: ...S2600E CLI Reference Guide Chapter 10 DHCP Snooping Configuration Commands Examples Command Description Related commands...
Страница 877: ...S2600E CLI Reference Guide Chapter 16 Ruijie Switch Security Compatible Mode Configuration Commands...
Страница 878: ...ACL QOS...
Страница 953: ...Reliability...
Страница 985: ...S2600E CLI Reference Guide Chapter 4 Warm Reload Upgrade Configuration Commands Platform Description None...
Страница 1011: ...S2600E CLI Reference Guide Chapter 5 SRM Configuration Commands Command Description Related commands Platform description...
Страница 1012: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands 6 GRTD Configuration Commands 6 1 Configuration Related Commands...
Страница 1024: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands Platform description...
Страница 1027: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands Platform description 6 2 Test Related Commands...
Страница 1029: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands commands None Platform description...
Страница 1031: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands Platform description...
Страница 1035: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands 6 3 Display Related Commands...
Страница 1121: ...System Management...