Protocol Analysis
R&S
®
RTM20xx
191
User Manual 1317.4726.02 ─ 01
Most settings are the same as for identifier input. See:
●
●
●
●
●
Remote command:
Data Length ← Data Setup ← Identifier and data
Defines the length of the data pattern - the number of bytes in the pattern.
Remote command:
11.5.3 CAN Label List
Label lists are protocol-specific. A PTT file for CAN contains three values for each iden-
tifier:
●
"Type": identifier type, 11-bit or 29-bit long
●
"ID / Addr": hexadecimal identifier value
●
"Symbolic label": symbolic name of the identifier, specifiing its function in the bus
network.
Example: CAN PTT file
# ----------------------------------------------------------------------------
@FILE_VERSION = 1.00
@PROTOCOL_NAME = can
# ---------------------------------------------------------------------------
# Labels for CAN protocol
# Column order: Identifier type, Identifier value, Label
# ---------------------------------------------------------------------------
11,0x064,Diag_Response
11,0x1E5,EngineData
11,0x0A2,Ignition_Info
11,0x1BC,TP_Console
11,0x333,ABSdata
11,0x313,Door_Left
11,0x314,Door_Right
29,0x01A54321,Throttle
29,0x13A00FA2,LightState
29,0x0630ABCD,Engine_Status
CAN (Option R&S RTM-K3)