Remote Control
R&S
®
RTM20xx
353
User Manual 1317.4726.02 ─ 01
Suffix:
<m>
.
1..4
The numeric suffix is irrelevant.
Parameters:
<FreqSpan>
Range:
Depends on various other settings, mainly on time
base and span/RBW ratio.
Increment: Only 1 | 2 | 5 in first digit
Default unit: Hz
CALCulate:MATH<m>:FFT:STARt
<StartFreq>
Defines the start frequency of the displayed frequency domain at the left display edge:
Center - Span/2
You can set start and stop frequency instead of defining a center frequency and span.
Suffix:
<m>
.
1..4
The numeric suffix is irrelevant.
Parameters:
<StartFreq>
Range:
Depends on various other settings, mainly on time
base, span/RBW ratio, and center frequency.
Default unit: Hz
CALCulate:MATH<m>:FFT:STOP
<StopFreq>
Defines the stop frequency of the displayed frequency domain at the right display edge:
Span/2
You can set start and stop frequency instead of defining a center frequency and span.
Suffix:
<m>
.
1..4
The numeric suffix is irrelevant.
Parameters:
<StopFreq>
Range:
Depends on various other settings, mainly on time
base, span/RBW ratio, and center frequency.
Default unit: Hz
CALCulate:MATH<m>:FFT:TIME:RANGe
Defines the width of the time base extract from the Y(t)-window for which the FFT is
calculated.
Parameters:
<WindowWidth>
Range:
depends on the time base
Default unit: s
Firmware/Software:
FW 03.800
Command Reference