Mixed Signal Option (MSO, R&S
RTM-B1)
R&S
®
RTM20xx
209
User Manual 1317.4726.02 ─ 01
The following measurement types are available for single digital channels (bits): fre-
quency, period, edge and pulse counts, phase, delay, duty cycle, burst width. Statistical
evaluation of these measurements is also possible.
12.2 Digital Channels
12.2.1 Digital Channels - Configuration Settings
Access: PROTOCOL LOGIC > if "Protocol" menu is displayed: "Logic"
D7-D0 / D15-D8
Enables or disables all digital channels of the pod at once.
Visible
Enables or disables individual digital channels.
Turn the navigation knob to select the digital channel, then press the knob to enable or
disable the channel.
Remote command:
Threshold
Opens the "Threshold" menu.
You can set the digital threshold in several ways:
●
The same threshold and hysteresis is used for all digital channels: Enable "Couple
Levels" and set the values.
●
Different thresholds and hysteresis are used for individual channel groups (nibbles):
Disable "Couple Levels" and set the threshold and hysteresis for each nibble.
Nibble ← Threshold
Selects a group of 4 digital channels for which the threshold and the hysteresis can be
set.
Threshold ← Threshold
Sets the threshold value for the selected nibble, or for all digital channels if "Couple Lev-
els" is enabled.
The threshold setting is available if "Technology" is "User Level".