Remote Control
R&S
®
RTM20xx
410
User Manual 1317.4726.02 ─ 01
TRIGger:A:CAN:DATA
<Data>
Defines the data pattern. The number of bytes in the data pattern is defined with
.
is set to
IDDT
.
Parameters:
<Data>
String containing binary pattern with max. 64 bit. Characters 0, 1,
and X are allowed. Make sure to enter complete bytes.
TRIGger:A:CAN:ACKerror
<AcknowledgeError>
Triggers on acknowledgement errors. An acknowledgement error occurs when the trans-
mitter does not receive an acknowledgment - a dominant bit during the Ack Slot.
is set to
ERRCondition
.
Parameters:
<AcknowledgeError> ON | OFF
*RST:
OFF
TRIGger:A:CAN:BITSterror
<BitStuffingError>
Triggers on bit stuffing errors.
See also:
is set to
ERRCondition
.
Parameters:
<BitStuffingError>
ON | OFF
*RST:
ON
TRIGger:A:CAN:CRCerror
<CRCerror>
Triggers on errors in the Cyclic Redundancy Check.
is set to
ERRCondition
.
Parameters:
<CRCerror>
ON | OFF
*RST:
OFF
TRIGger:A:CAN:FORMerror
<FormError>
Triggers on form errors. A form error occurs when a fixed-form bit field contains one or
more illegal bits.
is set to
ERRCondition
.
Command Reference