Rexroth IndraDrive FCS01.1
Parameterization
11-11
DOK-INDRV*--FCS01*****-IB01_EN-P
Parameter
Setting value / description / note
Device
Supervisor
Parameter
record
P114
Brake release time
S
P
0 ... 2.50 s
[ 0.00 ]
Electromagnetic brakes have a physically caused delayed reaction time on release. As a
result, the motor may start while the brake is still applied, causing the FC to fail and
indicate an overcurrent error. This release time can be taken into consideration by
parameter P114 (brake control).
During release time, the FC supplies the absolute minimum frequency (P505), thus
preventing starting of the motor with the brake still applied.
Also refer to the parameter >Brake application time< P107 (sample setting).
Note:
If the brake release time is set to "0", P107 also applies as brake
release and application time.
Содержание IndraDrive Fc FCS01
Страница 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 237: ......