11-16
Parameterization
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
P220
Parameter identification
The FC automatically determines the motor data via this parameter. In the vast majority of
cases, this results in a significantly improved drive behavior as the asynchronous DS motor
is subject to certain manufacturing tolerances not documented on the type label.
The identification of all parameter will take some time. Do not switch off mains voltage.
Should you find an unfavorable operating behavior, select a suitable motor in P200 or set
the parameters P201…P208 manually.
... up to 240 s
0 =
No identification
1 =
Parameter identification R
S
: Only stator resistance P208 is determined.
2 =
Parameter identification motor parameter
: the parameters P201…P209 are
determined.
Procedure:
•
Motor data identification must take place with the motor
cold and at standstill
and
without release having been given for the FC. The heating of the motor is constantly
taken into consideration during operation.
•
The motor rating must be not more than one rating class larger or 3 rating classes
smaller than the rated power of the FC. Motor cable length should not exceed 20 m.
•
The motor data should be preset in accordance with the type label or P200. As a
minimum, however, the rated frequency (P201), rated speed (P202), voltage (P204),
power (P205) and motor connection (P207) must be known.
•
If the identification cannot be terminated successfully, error message E019 is
generated. Also refer to Chapter 12, Error Messages.
Note:
After parameter identification, P220 will be = 0 again.
Содержание IndraDrive Fc FCS01
Страница 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 237: ......