11-8
Parameterization
Rexroth IndraDrive FCS01.1
DOK-INDRV*--FCS01*****-IB01_EN-P
Parameter
Setting value / description / note
Device
Supervisor
Parameter
record
Ausgangs-
frequenz
jeweils
10 - 100% von P102
Zeit
P102
P103
jeweils
10 - 100% von P103
Sollfrequenz
Brake application time
P
0 ... 2.50 s
[ 0.00 ]
Electromagnetic brakes have a physically caused delayed reaction time on application.
This may result in sinking of load with lifting gear operations; the brake takes over the
load with a delay.
This application time of the brake can be taken into consideration by parameter P107
(brake control).
Within this application time, the FC will supply the absolute minimum frequency (P505)
and prevents sinking of load on stop.
In this context, also refer to parameter >Release time< P114
Note:
To control electromagnetic brakes (above all with lifting gear), an
internal relay should be used (function 1, external brake). The value
should not fall under 2.0Hz as an absolute minimum frequency
(P505).
Sample setting:
Lifting gear with
brake
P114 =
0.2...0.3sec.
P107 =
0.2...0.3sec.
P434 = 1
P505 = 2...4Hz
Output frequency
P107
Brake released
P114
or
P107, if P114 = 0
ON signal
P505
OFF signal
time
time
Output
frequency
set frequency
Respectively
10..100% of P102
Respectively
10..100% of P103
Содержание IndraDrive Fc FCS01
Страница 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Страница 237: ......