With setting 5 in parameter P543, the statuses of the control terminals
and the relays (MFR) can be transmitted:
Bit
Status
Bit 0-4
Digital input 1-5
Bit 5-11
reserved
Bit 12, 13
Relays 1 and 2
Bit 14, 15
reserved
Fig. 15-49: Status digital I/O
Actual Value 2 and Actual Value 3 - AV2 and AV3
When PPO type 2 or 4 is used in a transmission, two more actual values
can be transmitted to the control.
Actual value 2 (AV2) is sent in PCD4. The value to be transmitted can be
selected in P544 (actual bus value 2). The actual value 3 (AV3) can be
sent in PCD3 if actual value 1 is
not
a 32bit value. The value to be
transmitted can be selected in P545 (actual bus value 3). The scalings
correspond to those of actual value 1.