Edition: 003
Figure 20/2
HEADING button
with 2 LEDs
Activates Heading Control mode.
LED (upper, green) indicates the selected
steering mode.
LED (lower, yellow) indicates:
- Selected steering mode, but NautoPilot®
Operation Unit is inactive (control from a
second NautoPilot® Operator Unit).
The inactive NautoPilot® operator Unit
serves as a display only (OU Display is
displayed at the top right corner).
--
AS application:
Standby is displayed at the top right corner;
the Autopilot can be activated by pressing
the button Heading.
--
Standalone application:
Autopilot cannot be activated.
A switching over of the Main Steering
Switch to AUTO the lower LED is off and
the upper LED is alight (steering mode is
Heading Control.
Pos.
Designation
Remarks
Figure 20/3
COURSE button
with 2 LEDs
Activates Course Control mode.
LED (upper, green) indicates the selected
steering mode.
LED (lower, yellow) indicates selected steering
mode, but NautoPilot® Operation Unit is
inactive (control from a second NautoPilot®
Operator Unit).
Figure 20/4
Track button with 2
LEDs
Activates Track Control mode.
LED (upper, green) indicates the selected
steering mode.
LED (lower, yellow) indicates selected steering
mode, but NautoPilot® Operation Unit is
inactive (control from a second NautoPilot®
Operator Unit).
Activation of Track Control at the Autopilot is
possible with a generic ECDIS only. Further-
more, it is not possible with an NP5500. If
Track Control cannot be activated the
Autopilot, an error message will be displayed.