10000001052
1.2 Technical Data
1.2.1
Mechanical Data
For dimensions, type of enclosure and weight see the appended
Dimensional Drawing 102- 890.HP005 for Autopilot 102- 890.NG001,
Dimensional Drawing 102- 890.HP015 for Autopilot 102- 890.NG002,
NG003.
1.2.2
Electrical Data
Supply voltage (plug B12)
24 V DC (18 to 36
V DC) Power consumption
Approx. 25 W
Ambient temperature (operation)
- 25
C to +55
C
Ambient temperature (storage)
- 40
C to +70
C
Outputs (Status):
- Status and alarm contacts
(plugs B3, B4, B5 and B6)
Output load 30 V DC, Imax. 1 A
Inputs (Status):
Status (plugs B10 and B11)
24V DC, Imax. 5 mA
Outputs/Inputs:
Serial in/out (plugs B8 and B9)
RS422 (NMEA)
CAN bus (plugs B21 and B22)
according to RAN CAN bus
specification LAN
(ETHERNET)
Signal Inputs:
Gyro Compass, Satellite Compass Course Bus or
NMEA* Magnetic Compass/Fluxgate Course
Bus or
NMEA* Speed Log
Course
Bus
or
NMEA*
Position Receiver
NMEA*
ECDIS (for Track Control)
according to IEC 62065,
APB NMEA*
*NMEA according to IEC 61162- 1, - 2