Chapter 6: SX II Administration
127
Trap
Description
networkFailure
An Ethernet interface of the product can no longer communicate
over the network.
networkParameterChanged
A change has been made to the network parameters.
networkParameterChangedv2 A change has been made to network parameters when working in
dual LAN isolation mode.
passwordSettingsChanged
Strong password settings have changed.
pduConnected
A power strip was connected to SX II.
pduDisconnected
A power strip was disconnected from SX II.
portConnect
A previously authenticated user has begun a session.
portConnectv2
When in dual LAN isolation mode, a previously authenticated user
has begun a session using a separate IP address.
portConnectionDenied
A connection to the target port was denied.
portDisconnect
A user engaging in a session closes the session properly.
portDisconnectv2
When in dual LAN isolation mode, a user engaging in a session
closes the session properly.
portStatusChange
The port has become unavailable.
powerNotification
The power outlet status notification: 1=Active, 0=Inactive.
powerOutletNotification
Power strip device outlet status notification.
rebootCompleted
The SX II has completed its reboot.
rebootStarted
The SX II has begun to reboot, either through cycling power to the
system or by a warm reboot from the OS.
securityBannerAction
Security banner was accepted or rejected.
securityBannerChanged
A change has been made to the security banner.
securityViolation
Security violation.
setDateTime
The date and time for the device has been set.
setFIPSMode
FIPS mode has been enabled.
startCCManagement
The device has been put under CommandCenter Management.
stopCCManagement
The device has been removed from CommandCenter Management.
sxPortAlert
An alert was triggered for the port.
userAdded
A user has been added to the system.
userAuthenticationFailure
A user attempted to log in without a correct username and/or
password.
userDisconnectedFromPort
A user disconnected from a target port properly.
Содержание Dominion SX II
Страница 75: ...Chapter 5 Raritan Serial Console RSC Help 68 2 Click Yes when prompted to confirm...
Страница 130: ...Chapter 6 SX II Administration 123 6 Click OK...
Страница 165: ...Chapter 6 SX II Administration 158 17 Click OK Apply Settings to Other Ports...
Страница 187: ...Chapter 6 SX II Administration 180 5 To page through the audit log use the Older and Newer links...
Страница 260: ...253 Dominion SX II Overview Appendix C FAQs...
Страница 267: ...Appendix C FAQs 260 Installation Management Configuration...