Chapter 6: SX II Administration
142
Power Supply Setup
SX II provides dual power supplies, and can automatically detect and
provide notification regarding the status of these power supplies.
When both power supplies are used, SX II automatically detects them
and notifies you of their status. Additionally, both the Powerln1 and
Powerln2 Auto Detect checkboxes are automatically selected on the
Power Supply Setup page.
If you are using only one power supply, you can enable automatic
detection for only the power supply in use.
Proper configuration of power supplies ensures SX II sends the
appropriate notifications should a power supply fail. For example, if
power supply number one fails, the power LED at the front of the unit will
turn red.
The Power LED on the front of the SX II appliance is red when one or
both of these checkboxes is selected, and only one power input is
connected.
If power inputs are connected to SX II, the power LED is red regardless
of the selection you make on the Power Supply Setup page.
To enable automatic detection for the power supplies in use:
1. Choose Device Settings > Power Supply Setup. The Power Supply
Setup page opens.
Содержание Dominion SX II
Страница 75: ...Chapter 5 Raritan Serial Console RSC Help 68 2 Click Yes when prompted to confirm...
Страница 130: ...Chapter 6 SX II Administration 123 6 Click OK...
Страница 165: ...Chapter 6 SX II Administration 158 17 Click OK Apply Settings to Other Ports...
Страница 187: ...Chapter 6 SX II Administration 180 5 To page through the audit log use the Older and Newer links...
Страница 260: ...253 Dominion SX II Overview Appendix C FAQs...
Страница 267: ...Appendix C FAQs 260 Installation Management Configuration...