Chapter 6: SX II Administration
74
2. Click OK. The outlet then cycles (note that this may take a few
seconds).
3. Once the cycling is complete a dialog will open. Click OK to close the
dialog.
Specify Power Cycle Duration
To specify the duration between powering an outlet off and on when the
cycle command is given, enter it in the "Power Cycle Duration (5-300
seconds)" field and select Set.
Note: If you are connecting a PX to SX II, it is recommended you set the
power cycle time to 5 seconds.
Connect and Configure a Rack PDU (Powerstrip)
SX II allows you to connect rack PDUs (power strips) to SX II ports. You
must configure these ports as power port via the SX II Port Configuration
page.
A special Raritan cable or CSCSPCS -1 Rev.0C adapter is required to
connect an SX II port to the Feature port of rack PDU.
Only Raritan rack PDUs are supported.
1. Configure an SX II port as power port.
2. On the Port Configuration page, click the port connected to power
strip to open its Port Edit page.
3. Change the port type from "Serial" to "Power Strip".