Pratt & Whitney Rzeszów S.A.
MAINTENANCE MANUAL
PZL-10W ENGINE
71-02-00
2015.12.30
Page 402
Export Control Classification: PL/UE 9E999
(3)
Put thin layer of leak stopper (see 72-02-00, Table 202, item 10) on the adjacent
surface of power turbine casing flange.
(4)
Install the exhaust duct on the engine and fasten it using the same bolts (12) and
washers (removed at removal) and new selflocking nuts (11), (see 72-02-00, Table
203, item 57).
NOTE: Work in accordance to item (4) shall be performed by two workers.
(5)
Place the halfrings (8): upper halfring (with cutout for part of power turbine speed
limiter drive casing) on the upper part of power turbine casing, and lower one on the
lower part of the power turbine casing. Fasten them by the bolts (10) together with
the washers (removed at removal) and new selflocking nuts (11) (in the same way as
at item (4)).
(6)
Screw in the remaining bolts (12) together with the washers (removed at removal)
and the selflocking nuts (11) (in the same way as at item (4)).
(7)
Tight on finally the nuts (11) on the bolts (10) and (12) with the torque of 3,4 ÷ 3,9 Nm
(0,35 ÷ 0,40 kGm; 30 ÷ 35 lb.in.).
(8)
Locate the shields (2) on the power turbine casing and screw in initially the bolts (5)
with new washers (6) (see 72-02-00, Table 203, Item 17).
(9)
Place the shields (1) at the accessory gearbox and fasten them by the bolts (5) with
new washers (6) (see 72-02-00, Table 203, item 17).
(10) Put the inner shield (4) and the exhaust manifold shield (3) on the exhaust manifold
and fasten it with the bolts (5) and new washers (6) - (refer to Table 203, item 17),
then slightly tighten the shields together (3) using the bolts (9).
(11) Tighten all the shield fastening bolts (5) using torque of 3.4 to 3.9 Nm (0.35 to 0.40
kGm; 30 to 35 lb-in). Bend all washer tabs (6) after tightening the bolts (5). Tighten
the fastening bolt nuts (9) evenly so that the shields (3) are slightly supported (with
the knurled spacer rings bonded to the shields) against the exhaust manifold but do
not become deformed - (indivative nut tightening torque is ca. 0.98 Nm (0.1 kGm; 8.6
lb-in)). Secure the nuts on the bolts (9) with safety wire.
D.
Direction Change of the Compressor 6th stage air bleed valve outlet
(see 75-32-00, Dwg. 401).
(1)
Unlock and unscrew the nuts of pipes (7) and (11), and remove the pipes from the
engine.
(2)
Unlock the bolts (6) and (12), and screw them out.
(3)
Remove the cover (5) from the valve, and the outlet (3) from the cylinder (2).
(4)
Situate the outlet (3) on the cylinder (2) pointing it to the direction depending on the
engine configuration.
(5)
Fasten the cross-bar (17) to the cover (5) by the bolts (6).